Unit battery maintenance knowledge

Update time:2018-6-5

At present, the most famous enterprise in China is Shandong comller, which is known as comller international. It is mainly devoted to high and low voltage generator, power generation system and high technology research and development of internal combustion engine. It provides high end generator and power generation to the mainland and all over the world. Unit power supply system project technical scheme and high performance, high quality products. The following diesel generator sets analyze the maintenance and maintenance of battery units for customers.
If the battery of diesel generator set is not used for a long time, it should be properly charged before use to ensure the normal capacity of the battery. In the normal operation and charging process of the technician, the part of the water inside the battery will be evaporated; therefore, it is necessary to make the rehydration of the unit battery. The first step is to clean the dirt around the filling mouth, in order to prevent the contamination falling into the battery, then the filling mouth is opened, and a proper amount of distilled water or pure water is added. Do not add to the full, otherwise, when the battery discharge / charge, the internal electrolyte of the diesel engine will come out of the overflow Kong Yong from the injection port, causing corrosion damage to the surrounding objects and the environment.
Diesel generating set is a power supply equipment driven by diesel engine and driven by synchronous generator. It is a kind of power generating device with quick start, easy operation and maintenance, less investment and strong adaptability to the environment.
To avoid the battery starting unit at low temperature, the battery capacity will not be able to normal output in low temperature environment, and long-term discharge may cause battery failure. Batteries for standby generators should be regularly maintained for battery charging and equipped with floating chargers.
Small skills in maintenance of diesel generators:
First, check whether the battery is charged properly. If you have a three-meter, after starting the engine, measure the voltage on both poles of the battery, it must be more than 13V before it is normal. If the charging voltage is too low, it is necessary for the professional to overhaul the charging system.
If you don't have a three-meter, you can use visual measurement: after the engine starts, open the battery and water cap to see if there are bubbles in each cell. The normal condition is that there are bubbles coming out of the water, and the more you get, the more you get. If you find no bubbles, it's likely to be something wrong with the charging system. Special attention is to do this test will produce hydrogen, so the test must not smoke, in order to avoid the risk of explosion and fire.
Open the battery and add the water cover to see if the water level is in normal position. Generally, there are upper and lower markings on the side of the battery for your reference. If the water level is below the subscript line, distilled water must be added. If distilled water is not available at once, filtered tap water can be used for emergency response. Water can not be added too much, the standard is added to the middle and lower marking.
Thirdly, wipe the battery with a wet cloth, wipe the dust, grease, white powder on the panel, pile head and other easily cause leakage of electricity. This often scrubbing battery, the pile head of the battery will not produce white acid etching powder, and its service life will be longer.